Improved sample preparation for determination of phosphoramidates in water samples based on Na+ cat-ion exchange
Publish date: 2006-01-01
Report number: FOI-R--1988--SE
Pages: 9
Written in: English
Keywords:
- Chemical warfare agents
- Phosphoramidate
- Sample preparation
- Cat-ion exchange
Abstract
A new (Na+) cat-ion exchange method for CWA sample preparation was evaluated. The new method prevents the acidification of samples associated with the use of exchangers in H+-mode. The acidification may induce hydrolysis if sensitive chemicals are contained in samples of high salinity. During "the 14th OPCW Proficiency Test" this problem was observed when a phosphoramidate was hydrolysed during sample preparation according to the standard cat-ion exchange method. Use of the new method was shown to prevent this degradation.